Failure Analysis of Steel Wire‐Reinforced Composite Pipes for Gas Field Flowback Fluid
Han Ding, Houbu Li, Guoquan Qi, Jiayu Bao, Zhao Zhang, Huilin Lun, Chong Liu, Ting Lei
Key points
From the paper's conclusion- To clarify the failure mechanism of steel wire‐reinforced thermoplastic (SWRTP) pipes in flowback fluid pipelines, failed and intact samples were systematically investigated.
Abstract
To clarify the failure mechanism of steel wire‐reinforced thermoplastic (SWRTP) pipes in flowback fluid pipelines, failed and intact samples were systematically investigated. Compression cracking and hydraulic burst tests confirmed the original intact pipe met standard requirements. The failed pipe exhibited circumferential cracking near the metal joint, displaying environmental stress cracking (ESC) characteristics. Morphological and spectroscopic analyses revealed complex electrochemical corrosion of the steel wires driven by CO 2 , HCO 3 − , and SO 4 2− species from the penetrating fluid. Furthermore, thermal analysis showed a localized oxidation induction temperature (OIT) decrease at the fracture surface (209.84°C), suggesting but not definitively proving service‐induced antioxidant depletion. The failure is proposed to be ESC, possibly attributed to metal‐joint crimping stress and the flowback chemical environment synergistically degrading the resin matrix. Crucially, it is hypothesized that antioxidant depletion and crack propagation mutually accelerated localized polymer embrittlement. Subsequent fluid ingress caused severe electrochemical corrosion of the steel wires, drastically reducing the pipe's pressure‐bearing capacity and ultimately leading to inside‐out penetrating cracks.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microbiologically assisted stress corrosion cracking of X80 pipeline steel welded joint under cathodic protectionActa Materialia · 2025
- Corrosion–Fatigue Damage Characteristics and Evolution Mechanisms of Failed Sucker RodsProcesses · 2026
- Corrosion Failure Analysis of a Reducing Tee at a Shale Gas StationCorrosion and Materials Degradation · 2026
- Failure Analysis of Acid-Thinned Coiled Tubing Under HTBH Conditions: Role of Inhibitor Depletion and Corrosion Asymmetry.Materials (Basel, Switzerland) · 2026
- Comparative study of composite and steel sleeve crack arrestors for mitigating running ductile fracture in CO2 pipelines using fluid-structure interaction analysesEngineering Fracture Mechanics · 2026
- Analysis of Leakage Causes of 6ADG011VR Branch Pipe in a Power PlantSAE technical papers on CD-ROM/SAE technical paper series · 2026