A Smart Self‐Immobilization Magnetic Resonance Contrast Agent for Delayed Tumor Imaging In Vivo
Zheng Huang, Yinxing Miao, Chunmei Lu, Jie-wei Luo, Yan Zhang, Deju Ye
Nanjing University · Fujian Medical University
Key points
From the paper's conclusion- Here, we present P‐QM‐Gd , an enzyme‐responsive, self‐immobilizing small‐molecule MRI probe designed for high‐sensitivity tumor imaging.
Abstract
Abstract Achieving tumor‐specific accumulation and high relaxivity remains critical yet challenging for improving magnetic resonance imaging (MRI) probe sensitivity. Here, we present P‐QM‐Gd , an enzyme‐responsive, self‐immobilizing small‐molecule MRI probe designed for high‐sensitivity tumor imaging. Upon activation by membrane‐bound alkaline phosphatase (ALP), P‐QM‐Gd is enzymatically converted to generate reactive quinone methide intermediates. These intermediates readily undergo nucleophilic addition with proximal protein residues, enabling the covalent conjugation of paramagnetic gadolinium complexes directly onto tumor cell membranes. This enzymatic self‐immobilization markedly increased the longitudinal relaxivity ( r 1 ) from 7.35 to 13.15 mM −1 s −1 (0.5 T, 21.3 MHz, 32 °C) and effectively “traps” the probe at the tumor site. P‐QM‐Gd showed rapid tumor uptake and efficient covalent labeling, achieving distinct MR contrast enhancement (> 60%). The imaging window was extended for up to 24 h in subcutaneous HeLa and orthotopic K7M2 tumor models. Notably, delayed MRI with P‐QM‐Gd enabled precision visualization of ∼1.3 mm orthotopic K7M2 tumors in mice. By overcoming the rapid washout and low sensitivity inherent to traditional small‐molecule MRI probes through this enzymatic self‐immobilization strategy, P‐QM‐Gd offers a promising approach for high‐sensitivity, high‐spatial resolution delayed tumor MRI, making it particularly effective for early‐stage lesion detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A GGT-Activatable Chiral Gadolinium Polymer Probe for Dual-Modal MR/NIRF Imaging of Glioma.Advanced healthcare materials · 2026
- Glutathione-Triggered Synergistically Enhanced Dual-Modality Magnetic Resonance Imaging for Tumor Diagnosis.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Metal−Ligand Separation Strategy Minimizes Off-State Relaxivity in Activatable T 1 MRI Contrast AgentsAnalytical Chemistry · 2026
- Enzyme-Activatable Probe for Tumor Bimodal Imaging, Intraoperative Navigation, and Urinalysis.Advanced healthcare materials · 2026
- Singlet Oxygen-Responsive MRI Contrast AgentsChemical & Biomedical Imaging · 2026
- Design Strategy of T1-Weighted MRI Contrast Agents for High Relaxivity Based on a Self-Folding Macromolecular Architecture.ACS applied materials & interfaces · 2026