Ferroptosis‐Impelled NIR Cyanine Dyes in Situ Generation Enabled Zero‐Background Fluorescence Imaging and Precise Surgical Tumor Excision
Xiunan Xie, Zhihao Lü, Yuerui Kong, Chenye Jin, Ziyan Sun, Xiaoling Yang, Zan Li, Fengli Qu,
Qufu Normal University · Zhejiang Cancer Hospital
Key points
From the paper's conclusion- In vivo experiments further demonstrated that Cy420 enables accurate zero‐background NIR imaging in sorafenib‐administrated xenograft hepatic tumor, with significantly enhanced tumor‐to‐background ratio (TBR 13.2 ± 0.74) at 72 h, competently empowered NIR fluorescence‐navigated precise tumor resection.
Abstract
Abstract The diagnostic accuracy of fluorescence imaging enabled lesion site visualization and pathological biomarker quantification is often compromised by non‐specific probe activation and “high‐background” fluorescence interference, which contribute to false‐positive signals and reduced signal‐to‐noise ratio, ultimately limiting clinical reliability. Herein, we propose a “zero‐background” fluorescence imaging strategy for precise quantification and evaluation of hydroxyl radical (·OH) levels in sorafenib‐provoked ferroptotic tumor. This study utilizes endogenous ·OH generated during tumorous ferroptosis as biocatalyst, triggering the heterogenous dimerization of monomers for directly in‐situ formulating near‐infrared (NIR) emissive cyanine dyes. The octadecyl‐substituted monomer (Cy420) demonstrated morphological variations from orbicular to square nano‐assemblies modulated with serum albumin and realized the targeted and prolonged retention in tumors facilitated with the enhanced permeability and retention (EPR) effect. Crucially, the in situ generated NIR dye (mCy849) forms a shielding effect via hydrophobic bis‐octadecyl chain‐driven self‐assembly, thus resisting molecular oxidation and ensuring quantification accuracy. In vivo experiments further demonstrated that Cy420 enables accurate zero‐background NIR imaging in sorafenib‐administrated xenograft hepatic tumor, with significantly enhanced tumor‐to‐background ratio (TBR 13.2 ± 0.74) at 72 h, competently empowered NIR fluorescence‐navigated precise tumor resection. Our strategy has provided a new paradigm for chemotherapy‐imaging synergistic regulation of tumors with authentic “zero‐background” fluorescence.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ferroptosis‐Impelled NIR Cyanine Dyes in Situ Generation Enabled Zero‐Background Fluorescence Imaging and Precise Surgical Tumor ExcisionAngewandte Chemie International Edition · 2025
- Recent Advances in Near-Infrared Cyanine Dye-Based Fluorescent Nanoprobes for Tumor Imaging and TherapyInternational Journal of Nanomedicine · 2025
- Controllable Self-Assembly of Amphiphilic Heptamethine Cyanines for Turn-On Fluorescence-Guided Tumor PhototherapyAnalytical Chemistry · 2025
- Aggregation‐Enhanced Asymmetric Heptamethine Cyanine Nanoplatform for Imaging‐Guided Synergistic Phototherapy and FerroptosisAggregate · 2025
- An N-Alkylpyridinium-Substituted Cyanine Platform for Constructing Renal-Clearable Near-Infrared Fluorogenic ProbesJournal of the American Chemical Society · 2025
- Near-Infrared Ratiometric Fluorescent Probe for Monitoring Hypochlorous Acid in Ferroptosis ModelsAnalytical Chemistry · 2025