Gel-Free Capture of Microvolt-Level Neural Signatures Via a 3D Monolithic Carbon Fiber Dry Electrode.
Haoxuan Sun, Nikolay Novitskiy, Dongwook Jang, Yixiang Liu, Shaoqi Pan, Ting Huang, Yitong Li, Huisi Yang,
Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, SAR, China. · Brain and Mind Institute, The Chinese University of Hong Kong, Hong Kong, SAR, China.
Key points
From the paper's conclusion- These results demonstrate gel-free acquisition of weak neural biomarkers, opening a pathway toward prolonged, preparation-free neurophysiology.
Abstract
Gel-based wet electrodes remain the gold standard for electrophysiology, but gel dehydration limits recordings. Existing dry electrodes partially address this limitation but suffer from high interfacial impedance. Here, a carbon fiber-based porous electrode (CFPE) is reported, comprising a three-dimensional conductive network coated with poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS). The CFPE establishes contact at hairy-scalp sites with an impedance of approximately 10 kΩ·cm2. On the forearm, its impedance at 10 Hz without skin preparation is 11.09 ± 1.03 kΩ·cm2, compared with 13.57 ± 2.07 kΩ·cm2 for wet electrodes. After 6 h of wear, CFPE impedance reaches 1.3 times its initial value without skin preparation or gel, whereas wet-electrode impedance reaches 56 times its initial value when applied with skin preparation and conductive gel. High-fidelity electrocardiography, electromyography, and electroencephalography signals are captured with correlation coefficients exceeding 90% and signal-to-noise ratios comparable to wet electrodes. The CFPE further resolves microvolt-level speech-evoked frequency-following responses (FFR) and long-latency responses (LLR), with fidelity comparable to wet electrodes and significantly higher LLR SNR. These results demonstrate gel-free acquisition of weak neural biomarkers, opening a pathway toward prolonged, preparation-free neurophysiology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-day recalibration-free electrophysiology interface based on carbon nanotube thin film dry electrodes.Nature communications · 2026
- Flexible Microneedle Array Electrode with Improved Comfort, Low Impedance, and High Performance for Electrophysiological Recording.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Conformal and adhesive gel for stable electrophysiology on hairy animals without shavingNature Communications · 2026
- Bioinspired Epidermal Electrode With Excellent Environmental Tolerance and Adhesion for Robust Electrophysiological Monitoring.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Conformal Thermoreversible Gelatin-Based Gel for High-Fidelity Electrophysiological Recording and Acute Peripheral Nerve Interfacing.Advanced materials (Deerfield Beach, Fla.) · 2026
- Systematic Benchmarking of a Noise‐Tolerant Conductive Hydrogel Electrode for Epidermal BioelectronicsAdvanced Science · 2025