Immunomagnetic-MXene Bifunctional Probes for Ultrasensitive and Specific Terahertz Metasensing of Tumor-Derived Exosomes.
Weidong Jin, Jiyue Chen, Fengxin Xie, Huiyan Tian, Xuechen Dou, Yanqi Han, Lu Zhang, Jining Li,
Department of Laboratory Medicine, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing, China. · Institute of Laser and Optoelectronics, School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Key points
From the paper's conclusion- Antibodies against ZIP4 and glypican-1 (GPC-1) were separately conjugated to magnetic beads (MBs) and MXene nanosheets, which yielded two probes that simultaneously targeted PC-derived tExos, enabling highly specific sandwich-type capture of target exosomes.
Abstract
Tumor-derived exosomes (tExos) are promising biomarkers for early pancreatic cancer (PC) diagnosis, yet current detection methods are limited by cumbersome implementation, high sample consumption, and complex matrix interference. Herein, we developed immunomagnetic-MXene bifunctional probes coupled with terahertz (THz) metamaterials to synergistically increase the sensitivity and specificity of PC-derived tExos detection. Antibodies against ZIP4 and glypican-1 (GPC-1) were separately conjugated to magnetic beads (MBs) and MXene nanosheets, which yielded two probes that simultaneously targeted PC-derived tExos, enabling highly specific sandwich-type capture of target exosomes. Moreover, MXene increased the tExo-induced THz metamaterial resonance and outperformed AuNPs in signal amplification, endowing the method with a limit of detection (LOD) of 647 particles mL-1. The developed THz metasensor achieved accurate detection of early tumor formation and evaluation of therapeutic responses in PC mouse models. In a 60-subject clinical cohort, it distinguished all-stage PC patients from healthy controls with an area under the curve (AUC) of 0.997. Compared with that of the conventional CA19-9 assay, our THz metasensor demonstrated superior diagnostic accuracy in 11 early-stage PC patients (AUC: 0.991 vs. 0.809), with a simplified workflow, minimal sample requirement (10 µL), and low cost (< $5), highlighting its potential for clinical translation in early PC diagnosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Aptamer-Linked Terahertz Meta-Sensor for Sensitive and Specific Detection of Carcinoembryonic AntigenAnalytical Chemistry · 2025
- Quad-Band Terahertz Metamaterial Sensor Based on Dual Near-Perfect Absorption for Fingerprint Identification of Cancer Cells.Sensors (Basel, Switzerland) · 2026
- Graphene-enabled QBIC terahertz metamaterial biosensor for pancreatic cancer biomarker detectionOptics Express · 2026
- Advanced graphene–MXene–black phosphorus multilayered metasurface sensor for high-sensitivity terahertz brain tumor detectionAIP Advances · 2026
- Quad-Band Terahertz Metasurface Flexible Biosensor for HCC Biomarker Detection Using a Multipeak Data Fusion Strategy.ACS applied materials & interfaces · 2026
- Machine Learning-Enhanced Terahertz-Colorimetric Dual-Mode Metadevice Based on Metallic Nanonetworks for microRNA Panel Assays.ACS sensors · 2026