Advanced materials (Deerfield Beach, Fla.)

Bioinspired Membrane Fusion-Gated Hydrogel Biosensor for Extraction-Free Viral RNA Detection of Infectious Influenza Virus.

Byeonggeol Mun, Chaewon Park, Hansol Kim, Jaewook Lim, Yeonwoo Jeong, Seung Jae Oh, Inhee Maeng, Eun-Kyung Lim,

Department of Chemical and Biomolecular Engineering, College of Engineering, Yonsei University, Seoul, Republic of Korea. · Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon, Republic of Korea.

Key points

From the paper's conclusion
  • Here, we report a bioinspired membrane-coated hydrogel (Memgel) sensor that enables extraction-free molecular detection of influenza virus while distinguishing fusion-competent virions from noninfectious viral material.

Abstract

Emerging infectious diseases driven by zoonotic spillover demand rapid and reliable molecular diagnostics for pathogen identification and surveillance. However, conventional nucleic acid diagnostics cannot distinguish infectious virions from nonviable RNA fragments, limiting infectivity-resolved virus identification. Here, we report a bioinspired membrane-coated hydrogel (Memgel) sensor that enables extraction-free molecular detection of influenza virus while distinguishing fusion-competent virions from noninfectious viral material. The platform integrates a cell-mimetic supported lipid bilayer with a polyethylene glycol diacrylate (PEGDA) hydrogel matrix encapsulating recombinase polymerase amplification (RPA) reagents. Under endosome-mimicking acidic conditions, hemagglutinin-mediated membrane fusion selectively delivers viral genomic RNA from infectious virions into the hydrogel matrix, triggering sequence-specific amplification while suppressing signals from free viral RNA fragments. As a proof of concept, the Memgel sensor was evaluated for the detection of influenza A (H9N2) in simulated nasal fluid and raw milk matrices, achieving a limit of detection of 101.23 TCID50 mL- 1 while maintaining robust detection performance without RNA extraction. Coupled with a portable fluorescence reader, the system demonstrates compatibility with compact fluorescence-based readout for future point-of-care implementation. This fusion-gated sensing strategy provides a materials-based framework for infectivity-resolved molecular diagnostics of emerging viral pathogens.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Bioinspired Membrane Fusion-Gated Hydrogel Biosensor for Extraction-Free Viral RNA Detection of Infectious Influenza Virus — Science Skim