Advanced materials (Deerfield Beach, Fla.)

Fluoride-Mediated Host-Activator Engineering in Homogeneous Lithium Glass Scintillators for Thermal-Neutron Detection and Imaging.

Xiaoxin Zheng, Jinling Ma, Chuang Liu, Zhipeng Zhu, Puhuan Luo, Sikai Wang, Ruilin Zheng, Cailin Wang,

Key Laboratory of In-Fiber Integrated Optics of Ministry of Education, College of Physics and Optoelectronic Engineering, Harbin Engineering University, Harbin, China. · Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China.

Key points

From the paper's conclusion
  • A transparent plate exceeding 2 inches further enables proof-of-concept two-dimensional thermal-neutron imaging with a system-level spatial resolution of 1.35 mm, demonstrating the scalability of the glass for position-sensitive neutron imaging.

Abstract

Homogeneous lithium-aluminosilicate-glass scintillators offer transparency, scalable fabrication, and compositional flexibility, but their neutron response is limited by defect trapping and activator loading concentration. Here, fluoride-mediated host-activator engineering is introduced to overcome these coupled limitations in Ce3+-activated lithium aluminosilicate glasses. F- preferentially coordinates with Li+ and Mg2+, preserving the primary Si/Al─O tetrahedral units while reorganizing inter-tetrahedral linkages. The resulting host-network reconfiguration suppresses electronic disorder and defect-mediated trapping, modulates medium-range Ce-centered correlations, broadens the viable Ce-concentration window, and enables efficient excitation capture at ∼9 wt% CeO2 (twice that of GS20). After 6Li enrichment, it delivers 8003 photons neutron-1, an energy resolution of 6.8%, a decay time of 85.06 ns, and a neutron peak-to-trough ratio of 77:1. To the best of our knowledge, these values represent the highest light yield and best energy resolution reported for a homogeneous transparent 6Li-enriched glass scintillator, achieving single-digit neutron energy resolution for the first time and approaching the performance of 3He proportional counters and high-performance crystalline scintillators. A transparent plate exceeding 2 inches further enables proof-of-concept two-dimensional thermal-neutron imaging with a system-level spatial resolution of 1.35 mm, demonstrating the scalability of the glass for position-sensitive neutron imaging.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fluoride-Mediated Host-Activator Engineering in Homogeneous Lithium Glass Scintillators for Thermal-Neutron Detection and Imaging — Science Skim