Advanced healthcare materials

Closing the Knowledge Gap on Terminal Sterilization of Elastin-Like Biohybrid Implants.

Dominic Pascal Andre, Alexander Loewen, Svenja Deichmann, Nicole Schaaps, Felix Vogt, Stephan Rütten, José Carlos Rodríguez-Cabello, Stefan Jockenhoevel,

Department of Biohybrid & Medical Textiles (BioTex), AME-Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany. · Department of Cardiology, Pneumology, Angiology and Intensive Care (Internal Medicine I), RWTH Aachen University, Aachen, Germany.

Review

Key points

From the paper's conclusion
  • By assessing mechanical parameters defined in ISO 7198, as well as bioactivity and hemocompatibility, we highlight how sterilization influences scaffold performance and emphasize the need for establishing graft-specific sterilization protocols early in development.

Abstract

Synthetic vascular grafts have been widely used for decades as one of the main treatment options for patients with cardiovascular diseases, as well as for establishing vascular access in individuals with end-stage renal disease. Despite their clinical utility, current synthetic grafts still face major limitations such as inadequate compliance, insufficient hemocompatibility and biocompatibility, and the inability to remodel or self-repair. These drawbacks often contribute to complications that significantly worsen patient outcomes. To overcome these shortcomings, textile-reinforced hydrogel scaffolds have emerged as promising alternatives, combining the mechanical stability of synthetic polymers with the biocompatibility of recombinant polypeptides. However, for successful clinical translation, it is not only the design and fabrication of such scaffolds that matter, but also the identification of suitable terminal sterilization methods. Sterilization can strongly affect graft properties, potentially altering mechanics or biological performance. We investigated the effects of three established terminal sterilization methods, autoclaving (AUTO), ethylene oxide (ETO), and gamma irradiation (GS), and their associated processing routes on textile-reinforced biohybrid vascular grafts. By assessing mechanical parameters defined in ISO 7198, as well as bioactivity and hemocompatibility, we highlight how sterilization influences scaffold performance and emphasize the need for establishing graft-specific sterilization protocols early in development.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Closing the Knowledge Gap on Terminal Sterilization of Elastin-Like Biohybrid Implants — Science Skim