Pressure-Assisted Drug Delivery Using High-Pressure Balloon Platform Improves Vascular Drug Penetration and Anti-Restenotic Effects.
Seung Jin Eo, So Yun Lim, Dong-Sung Won, Ji Won Kim, Yubeen Park, Song Hee Kim, Hyemin Lee, Jung-Min Ahn,
Department of Convergence Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. · Biomedical Engineering Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul, Republic of Korea.
Key points
From the paper's conclusion- These findings support DCB use based on a dual-layered HP balloon platform as a promising next-generation strategy for stenotic vascular lesion treatment.
Abstract
High-pressure drug-coated balloon (HP@DCB) angioplasty enhances vascular drug delivery by overcoming the limitations of passive diffusion-based conventional noncompliant DCB (NC@DCB) systems. We developed a dual-layer HP balloon catheter composed of an outer Nylon 12 layer and an inner Pebax 7233 layer, and evaluated its feasibility and therapeutic efficacy as a paclitaxel (PTX)-coated platform. Shellac-based PTX coating was uniformly applied to HP@DCB and NC@DCB, and coating thickness, drug amount, release behavior, and mechanical properties were compared. Pressure-assisted drug penetration was assessed in a vascular-mimicking agarose gel phantom using fluorescent PTX and confocal microscopy. In vivo efficacy was evaluated in a balloon injury-induced rabbit iliac artery stenosis model using angiography, optical coherence tomography (OCT), histology, immunohistochemistry, and immunofluorescence examinations. Drug amount, coating thickness, and sustained drug release did not differ between groups. The mechanical robustness in HP@DCB was significantly greater than that in NC@DCB. HP@DCB produced significantly greater penetration depth and fluorescence-positive area, indicating enhanced pressure-assisted drug transfer. HP@DCB resulted in superior luminal patency, reduced neointimal hyperplasia, and favorable biological responses compared with that in NC@DCB and the sham control. These findings support DCB use based on a dual-layered HP balloon platform as a promising next-generation strategy for stenotic vascular lesion treatment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Drug‐Coated Balloons in Coronary Artery Disease: Engineering, Pharmacology, and the Mechanisms Behind Angiographic OutcomesCatheterization and Cardiovascular Interventions · 2026
- Coronary Drug-Coated Balloons as Brief-Contact Drug-Delivery Platforms: Engineering, Tissue Pharmacokinetics, and Angiographic/Imaging Response.Medicina (Kaunas, Lithuania) · 2026
- A Mechanoresponsive Drug-Releasing Silk Balloon Catheter for Inflation-Triggered Biophysical and Biochemical Treatment of Cardiovascular Plaque.Small (Weinheim an der Bergstrasse, Germany) · 2026
- Development and proof-of-concept of an in vitro mesoscale pipeline for the biomechanical assessment of coating transfer and persistence onto the arterial wall in drug coated balloonsBiophysics Reviews · 2026
- Drug-coated balloons: from evidence to practice and a proposed antithrombotic therapy algorithm.REC, interventional cardiology · 2026
- Pharmacokinetics, Safety, and Exploratory 12-Month Clinical Follow-Up of a Novel BIOtorcin™-Coated Balloon for Femoropopliteal Artery Disease: The BRight PK Study.Biomedicines · 2026