Rational Control of Antibody Orientation for Enhancing Sensitivity and Specificity in Lateral Flow Immunoassays With Clinical Validation.
Pin-Hao Wang, Shunmuga Nathan Shunmuga Nainar, Bing-Han Zhuang, Shun-Mao Yang, Hong-Cheu Lin, Yang-Hsiang Chan
Department of Applied Chemistry, National Yang Ming Chiao Tung University, Hsinchu, Taiwan. · Department of Materials Science and Engineering, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
Key points
From the paper's conclusion- Furthermore, multiplexed LFAs using fluorescent polymer dots enabled simultaneous detection of CYFRA21-1 and CEA with minimal cross-reactivity and were validated in 28 clinical serum samples against the hospital reference method.
Abstract
Lateral flow assays (LFAs) are widely used for point-of-care diagnostics, but their sensitivity is often limited by inefficient antibody orientation and poor signal transduction. Herein, we report a universal strategy integrating orientation-controlled antibody conjugation at the immunoprobe with a biotin-streptavidin-modified test line to enhance LFA sensitivity, specificity, and analytical reliability. Using an orientation-controlled conjugation approach (P-6, Scheme 1), antigen accessibility was maximized while nonspecific adsorption and false-positive signals were suppressed. Compared with conventional randomly conjugated probes (P-3, Scheme 1) on unmodified test lines, the combined P-6/biotin-streptavidin configuration achieved limits of detection of 0.0352 ng/mL for cytokeratin 19 fragment (CYFRA21-1) and 0.0808 ng/mL for carcinoembryonic antigen (CEA), corresponding to sensitivity enhancements of approximately 14-19 fold. However, probe rankings get inverted across capture chemistries, indicating the importance of dual-site orientation. The universality of this strategy was further validated using alpha-fetoprotein (AFP), carbohydrate antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), and prostate-specific antigen (PSA). Furthermore, multiplexed LFAs using fluorescent polymer dots enabled simultaneous detection of CYFRA21-1 and CEA with minimal cross-reactivity and were validated in 28 clinical serum samples against the hospital reference method.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Boronate-mediated antibody orientation: a molecular simulation-guided strategy for ultra-sensitive lateral flow immunoassays.Mikrochimica acta · 2026
- A Rational Optimization Approach for the Development of a Multiplexed Lateral Flow Immunoassay: Detection of Nonepithelial Ovarian Cancer Markers in Human SerumAdvanced Science · 2026
- Precision antibody orientation on gold nanoparticles via pH control enables clinic-grade lateral flow detection of acute myocardial infarctionNano Materials Science · 2025
- Mitigating Interfacial Displacement via Abundance-Dependent Antibody Modification for SeNP-Based Multiple-Biomarker Biosensing.Analytical chemistry · 2026
- Affinity‐Switchable Fluorescent Probes for Lateral Flow Detection of Small Reactive Molecules and Enzymatic ActivitiesJournal of the Chinese Chemical Society · 2026
- Signal-Amplification Strategies for Gold-Nanoparticle Lateral Flow Assays: A Structured Review of Limit-of-Detection Improvement Relative to Conventional GNP-LFAChemistry · 2026