Flexible Photoelectrochemical Sensor Based on Dual Electric Field Enhanced Photothermoelectric Activity for Prehospital Diagnosis of Atherosclerosis
Lin Li, Weiwei Wang, Guoliang Zhang, Song Wang, Jinghua Yu, Zhiming Lu, Yan Zhang, Yunshan Wang,
Shandong Provincial Hospital · University of Jinan
Key points
From the paper's conclusion- ABSTRACT Developing a flexible photoelectrochemical (PEC) sensor for timely diagnosis of atherosclerosis (AS) progression during the prehospital period is crucial for mitigating the risk of disease deterioration.
Abstract
ABSTRACT Developing a flexible photoelectrochemical (PEC) sensor for timely diagnosis of atherosclerosis (AS) progression during the prehospital period is crucial for mitigating the risk of disease deterioration. However, the problem of thermally induced interfacial electron recombination, which compromises sensor sensitivity, poses a significant obstacle. Herein, a photothermal‐thermoelectric synergistic conversion strategy based on a dual electric field is proposed to regulate the directional migration of carriers at the PEC sensing interface, enabling sensitive detection of lipoprotein‐associated phospholipase A 2 (Lp‐PLA 2 ) in health monitoring scenarios. Benefiting from the fast charge transfer channel mediated by the Au bridge, the energetic built‐in electric field is established at the interface between the Au/CsPbBr 3 beacon unit and the CuCo 2 S 4 /Cu 2 O thermoelectric electrode. This configuration efficiently expedites the photogenerated electrons separation. Additionally, the localized temperature rise, induced by lattice relaxation in the Au/CsPbBr 3 , will further accelerate the transfer of thermal carriers by the thermoelectric field in CuCo 2 S 4 /Cu 2 O. This compensates for the stability limitation of the sensing signal caused by thermal effects and enhances the detection sensitivity of the sensor. Furthermore, the hydrolysis process between the 1‐palmitoyl‐2‐(5‐oxovaleroyl)‐sn‐glycero‐3‐phosphocholine and Lp‐PLA 2 enables the system to sensitively quantify the Lp‐PLA 2 levels in body fluid within the range of 1–1000 ng mL −1 , providing support for prehospital diagnostic capabilities for AS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- In Situ Ion-Exchange-Mediated Dynamic Nanointerface Reconfiguration for Polarity-Switchable Photoelectrochemical-Photothermal Biosensing.Journal of the American Chemical Society · 2026
- Review on Research Progress of Photoelectrochemical BiosensorsMicromachines · 2025
- Electrochemical detection of the ethyl acetate biomarker using a lead-free double perovskite for the early diagnosis of lung cancer.Journal of materials chemistry. B · 2026
- A Ratiometric Photoelectrochemical Biosensor Based on Polarity Reversal of Photocurrent Caused by Controllable Surface Defect Engineering.Analytical chemistry · 2026
- Visible-light-driven non-enzymatic photoelectrochemical glucose sensing using an Ag₂S/PANi-Nafion/ITO hybrid electrode for analysis of sports nutrition samples.Mikrochimica acta · 2026
- Self-Powered Anti-Interference Photoelectrochemical Immunosensor Enabled by a Ferroelectric Hybrid Coupled with a Platinum-Doped Peptide HydrogelAnalytical Chemistry · 2026