Development of a slice‐specific ct dose library with interpolation methods for organ dosimetry in MIRDct
Jared M. Baggett, Laura E. Dinwiddie, Robert J. Dawson, Juan C. Ocampo Ramos, Gunjan Kayal, Lukas M. Carter, Adam L. Kesner, Wesley E. Bolch
Key points
From the paper's conclusion- The resulting dose library and interpolation method will be integrated into the MIRDct platform, a dosimetry tool for calculating total organ dose values across a wide range of CT parameters.
Abstract
Objectives To develop a slice‐specific dose library and supporting interpolation scheme for proper estimation of organ doses from CT scans based on the UF/MSK mesh‐type adult and pediatric phantom series. Methods Monte Carlo (MC) simulations were performed using the Particle and Heavy Ion Transport code System (PHITS) for selected adult female and pediatric male phantoms across a user defined CT source term. Dose profiles were calculated on a 1‐cm slice basis and categorized by tissue type (distributed vs. non‐distributed). Linear interpolation of slice doses within a height series was evaluated using multiple phantom subsets and compared against MC results. Results Slice‐by‐slice linear interpolation produced total organ dose estimates within 5% of MC values for most studied tissues, with all errors below 7%. Mean errors for abdomen, chest‐abdomen‐pelvis and cardiac scan ranges were also below 5%, and mean errors for individual slices were below 3%. The method performed well across various interpolation schemes, especially when phantoms were selected based on similar construction methods. Conclusions This approach enables accurate, scalable organ dose estimation with reduced computational demands. The resulting dose library and interpolation method will be integrated into the MIRDct platform, a dosimetry tool for calculating total organ dose values across a wide range of CT parameters. MIRDct is freely available to the medical imaging community at MIRDsoft.org.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anatomy-Weighted CTDIvol from Routine CT Metadata: A Patient-Specific, Multi-Vendor Study Using Deep-Learning Segmentation.Tomography (Ann Arbor, Mich.) · 2026
- MIRD Pamphlet No. 34, Part 1: MIRDctA Customizable Software Tool for CT DosimetryJournal of Nuclear Medicine · 2026
- Survey of normalized CTDI vol values across four major computed tomography vendors for use in the MIRDct softwareJournal of Applied Clinical Medical Physics · 2026
- Physics-informed machine learning-based dose calculation for patients undergoing fluoroscopically guided interventional procedures.Physics in medicine and biology · 2026
- Fast Patient-Specific Breast CT Dosimetry: 22-Fold Acceleration of Monte Carlo MGD EstimationarXiv · 2026
- Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography.Journal of applied clinical medical physics · 2026