Comparison of visual and semiautomated analysis techniques for depth of visualization assessment in ultrasound quality assurance
Miia Nadhum, Anna Vuorenmaa, Ullamari Hakulinen, Antti Vehkaoja
Key points
From the paper's conclusion- Conclusion Semiautomated DoV analysis using UltraIQ is as repeatable and reliable as visual assessment while providing a more objective approach for US QA.
Abstract
Background Depth of visualization (DoV) measurements are recommended as part of routine ultrasound (US) quality assurance (QA) in international guidelines. Effective QA requires measurement and analysis procedures that are repeatable, reliable, and minimally operator‑dependent. Purpose This study compares three visual DoV analysis methods with semiautomated analysis tool UltraIQ to identify the approach with the highest repeatability and improved objectivity. Methods A total of 215 retrospective DoV measurements acquired between 2018–2022 were analyzed, including 40 transducer models from 14 US devices by six manufacturers. Visual DoV measurements were performed on the US system display and on a medical‐grade display using a Picture Archiving and Communication System (PACS) using the vertical distance group and the uniformity images obtained from QA Phantom. DoV was also evaluated using SNR‐based analysis in the UltraIQ software. Repeatability was evaluated using three repeated DoV measurements for 17 transducers, and reliability was assessed using the intraclass correlation coefficient (ICC). Results UltraIQ provided DoV values that were 5.0%–14.5% deeper than those obtained with visual methods. Visual DoV on the US device display was 0.7–2.0 cm shallower than UltraIQ and 0.1–0.9 cm shallower than visual DoV on PACS. Visual measurements using uniformity images on PACS were 0.4–1.1 cm shallower than UltraIQ but demonstrated the closest agreement with UltraIQ results. ICC analysis showed good to excellent reliability. For visually measured DoV, ICC values ranged 0.893–0.939, while UltraIQ provided an ICC of 0.882. Conclusion Semiautomated DoV analysis using UltraIQ is as repeatable and reliable as visual assessment while providing a more objective approach for US QA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-system evaluation of baseline-referenced gray scale CNR profile deviation for phantom-based ultrasound quality assurance.Journal of applied clinical medical physics · 2026
- Implementation of an automated diagnostic display quality assurance program.Physical and engineering sciences in medicine · 2026
- Automated echocardiography image quality assessment and its association with AI performancemedRxiv · 2026
- A new Deep Learning-Assisted Probe Navigation System for Transthoracic EchocardiographyACM Transactions on Computing for Healthcare · 2026
- The Need for Device-Specific Training Before Handheld Ultrasound Use: Agreement and Repeatability of Simulated Aortic Aneurysm Diameter Measurements by Senior Sonography Students on a Familiar Conventional and an Unfamiliar Handheld System.Diagnostics (Basel, Switzerland) · 2026
- Detecting Uniformity Artifacts in Ultrasound Transducers: Insights from Clinical Median Images and Deep Learning for Automatic Detection.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026