Improving deep-learning IMRT plan quality for lymphoma using deliverability-aware training.
Denis Kutnár, Ivan Richter Vogelius, Hristo Atanasov Georgiev, Lena Specht, Jens Petersen
Department of Computer Science, University of Copenhagen, Copenhagen Ø, Denmark. · Department of Oncology, Rigshospitalet, Copenhagen Ø, Denmark.
Key points
From the paper's conclusion- Cycle-consistency training improves the end-to-end deliverability of DL-generated IMRT plans for heterogeneous lymphoma, yielding substantially better TPS-recalculated, machine-deliverable plans than conventional dose-only supervision while maintaining sub-second fluence-map generation. However, statistically significant differences from the TPS reference remained for D98, D2, and Dmax.
Abstract
BACKGROUND: Deep learning (DL) methods have shown strong performance in predicting dose distributions from patient anatomy and target structures; however, accurate dose prediction does not guarantee a deliverable plan after conversion into machine parameters and dose recalculation in the treatment planning system (TPS), motivating training objectives that explicitly couple prediction to deliverability. Lymphoma presents substantial clinical heterogeneity in target location, extent, and prescription/fractionation, so fast automated methods that produce deliverable plans are particularly valuable. PURPOSE: To investigate whether a deliverability-aware training framework improves the end-to-end deliverability of DL-generated intensity-modulated radiotherapy (IMRT) plans for lymphoma. METHODS: A retrospective single-institution dataset of 619 plans (571 patients; 2009-2021) was used. Clinical volumetric modulated arc therapy (VMAT) plans were converted to standardized 15-field coplanar sliding-window IMRT reference plans in Eclipse using automated scripting. Two DL approaches were compared: a baseline dose-only objective model (DL-DO) and a multi-objective model (DL-MO) trained with dose supervision, fluence supervision, and a dose-fluence-dose cycle-consistency constraint implemented via fixed inverse and forward networks. Predicted fluence maps were imported into the TPS, leaf-sequenced, and recalculated with AcurosXB without further optimization; plan quality was evaluated on a held-out test set (n = 61) using planning target volume (PTV) D98, D2, and Dmax with paired Wilcoxon testing and Holm correction. RESULTS: DL-MO produced significantly better machine-deliverable plans than DL-DO, improving coverage and reducing hotspots (median paired differences: +12.31 percentage points (pp) in D98, -3.43 pp in D2, and -3.18 pp in Dmax; Holm-corrected p < 0.0001 for all). Mean ± SD PTV metrics were D98 = 90.10 ± 3.74% vs. 78.59 ± 5.92%, D2 = 106.28 ± 1.13% vs. 109.65 ± 2.40%, and Dmax = 110.32 ± 2.20% vs. 113.27 ± 3.03% (DL-MO vs. DL-DO). DL-MO approached the TPS reference IMRT plans (D98 = 91.62 ± 3.45%) with residual hotspot elevation. CONCLUSIONS: Cycle-consistency training improves the end-to-end deliverability of DL-generated IMRT plans for heterogeneous lymphoma, yielding substantially better TPS-recalculated, machine-deliverable plans than conventional dose-only supervision while maintaining sub-second fluence-map generation. However, statistically significant differences from the TPS reference remained for D98, D2, and Dmax.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- From Predicted Dose to Computationally Verified Plan: An End-to-End Deep Learning and Monte Carlo Pipeline for Automated VMAT Glioblastoma Radiotherapy.Journal of imaging informatics in medicine · 2026
- End-to-end automated radiotherapy planning using transfer learning to overcome data scarcity.Medical physics · 2026
- Efficient deep learning-driven workflows for accelerated single-fraction radiation therapy planning of a solitary tumour in the lung.Physics and imaging in radiation oncology · 2026
- A virtual physicist framework integrating dose prediction and large language models for automated treatment planning.Journal of applied clinical medical physics · 2026
- Multicenter study on the versatility and adoption of AI-driven automated radiotherapy planning across cancer typesNature Communications · 2025
- Quality assurance for deep learning-based proton therapy planning in routine clinical use for oropharyngeal cancer.Physics and imaging in radiation oncology · 2026