FEBS open bio

Experimental protocol for the application of multiphoton endoscopy to image biological tissues.

Vytautas Kučikas, Ida Peltoniemi, Sophie M L van de Walle, Mengyao Zhou, Marc A M J van Zandvoort

Department of Genetics and Cell Biology, Cardiovascular Research Institute Maastricht (CARIM), Research Institute for Oncology and Reproduction (GROW), Institute for Mental Health and NeuroSciences (MHeNS), Maastricht University, Maastricht, the Netherlands. · Faculty of Health, Medicine and Life Sciences, Maastricht University, Maastricht, the Netherlands.

Review

Key points

From the paper's conclusion
  • Together, this work provides a practical guide for implementing multiphoton endoscopy in experimental settings and highlights key considerations for adapting the technique to a broad range of biological applications.

Abstract

Multiphoton endoscopy has emerged as a promising extension of multiphoton microscopy, enabled by recent advances in nonlinear fiber optics. By combining optical sectioning, intrinsic contrast mechanisms, and flexible probe geometries, multiphoton endoscopy enables imaging in confined or nontraditional environments that are inaccessible to conventional benchtop systems. However, practical implementation remains challenging due to constraints imposed by probe miniaturization, scanning nonuniformity, and sample-dependent photodamage. Here, we present a practical multiphoton endoscopy protocol applying a commercially available, miniaturized two-photon endoscopic system. We describe system configuration, calibration procedures, and imaging strategies with a particular focus on spiral scan calibration and laser power ramping to compensate for non-uniform excitation across the field of view. The protocol is validated across a diverse set of reference materials and biological samples, including autofluorescent standards, three-dimensional smooth muscle cell constructs, rodent and human vascular tissues, brain sections, and plant leaves, involving both labeled and label-free imaging modalities. We discuss common pitfalls, limitations, and troubleshooting strategies encountered during routine operation, including photobleaching in thin histological sections and constraints arising from fixed excitation wavelength. Together, this work provides a practical guide for implementing multiphoton endoscopy in experimental settings and highlights key considerations for adapting the technique to a broad range of biological applications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers