科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ JAMA Network Open2026-03-16· Medicine

Incidence of Adverse Events in Peripheral Intravenous Vasopressor Use

Shang-Jun ZhangJian, Kuang-Yu Niu, C. L Philip Chen, Chen‐June Seak, Chieh‐Ching Yen

原始摘要(英文原文)· Original abstract
Importance: Peripheral intravenous (PIV) vasopressors are increasingly used but remain associated with adverse events (AEs). Quantifying the incidence of these AEs is essential to guide clinical decision-making regarding PIV vasopressor use. Objective: To assess the incidence of AEs and avoidance of central venous catheter (CVC) placement after PIV vasopressor administration in adults with hypotension, shock, or critical illness. Data Sources: PubMed, Embase, and the Cochrane Central Register of Controlled Trials were searched from inception to December 13, 2025, using medical subject headings and keywords related to peripheral vasopressors. Study Selection: Eligible studies included critically ill adults receiving vasopressors via PIV catheters and reported AEs and/or CVC avoidance. Data Extraction and Synthesis: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, 2 investigators independently extracted data and assessed risk of bias. A random-effects model was used, and proportions were pooled using a generalized linear mixed model. Main Outcomes and Measures: The primary end point was the pooled incidence of AEs as the proportion among total catheters, and the secondary end point was the pooled proportion of CVC avoidance. Results: Forty-nine studies including 33 060 catheters were analyzed. The pooled minor AE incidence was 2.6% (95% CI, 1.4%-4.7%) for norepinephrine, 0.0% (95% CI, 0.0%-24.6%) for epinephrine, 2.9% (95% CI, 1.8%-4.8%) for phenylephrine, 1.4% (95% CI, 0.3%-5.9%) for dopamine, 0.5% (95% CI, 0.1%-1.8%) for vasopressin, and 0.9% (95% CI, 0.1%-11.5%) for metaraminol. When considering all vasopressors collectively, the pooled minor AE incidence was 2.3% (95% CI, 1.5%-3.7%). Regarding major AEs, 30 venous thromboembolism events occurred, all in the 4 studies (8.1%) using midline catheters (1126 total catheters), with a pooled incidence of 1.4% (95% CI, 0.4%-5.4%). In contrast, only 1 major AE (a tissue necrosis event) was reported in 43 studies (87.8%) using short PIV catheters (29 596 total catheters), with a pooled incidence of 0.0% (95% CI, 0.0%-0.0%). CVC avoidance ranged from 0% to 100%, with a pooled proportion of 59.7% (95% CI, 46.4%-71.7%) in 38 studies (77.6%) including 15 371 catheters. Conclusions and Relevance: In this systematic review and meta-analysis of adult patients, AE incidence was low after short-term vasopressor administration through PIV catheters, particularly short catheters. These findings suggest that PIV administration might reduce the need for CVC placement with appropriate monitoring.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Incidence of Adverse Events in Peripheral Intravenous Vasopressor Use — 科研速览 Science Skim