Medical Imaging and Pediatric and Adolescent Brain Tumor Risk.
Diana L Miglioretti, Susan A Alber, Marilyn L Kwan, Priscila Pequeno, Erin J A Bowles, Robert T Greenlee, Natasha K Stout, Sheila Weinmann,
Department of Public Health Sciences, School of Medicine, University of California, Davis. · Division of Research, Kaiser Permanente Northern California, Pleasanton.
Key points
From the paper's conclusion- Medical imaging in children and adolescents was associated with a dose-related increase in brain tumor risk. These findings support careful clinical justification and dose minimization when pediatric imaging using ionizing radiation is indicated.
Abstract
IMPORTANCE: Ionizing radiation from medical imaging may increase brain tumor risk. OBJECTIVE: To quantify brain tumor risk associated with radiation exposure from medical imaging in children and adolescents. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort study of children born from 1996 through 2016 who were enrolled from birth in 6 US health care systems or Ontario, Canada, and were alive and cancer-free at age 2 years, with follow-up through December 31, 2017 (US sites), and December 31, 2024 (Ontario). EXPOSURES: Cumulative radiation dose to the brain from medical imaging, lagged by 2 years. MAIN OUTCOMES AND MEASURES: Incident brain or other central nervous system tumors. Hazard ratios (HRs) were estimated using Cox proportional hazards models for categorical dose, and excess relative risks (ERRs) were estimated using linear dose-response models for continuous dose. RESULTS: Among 3 704 860 children (1 900 285 [51.3%] male) followed up for 45 671 641 person-years (mean follow-up, 12.3 years), 1536 brain tumors were diagnosed. Mean radiation dose from 1 head computed tomography (CT) examination was 66.2 mGy (SD, 22.2). Among children with cumulative dose of 1 mGy or greater, mean cumulative dose was 73 mGy (SD, 95) overall and 100 mGy (SD, 105) among those diagnosed with brain tumors. Compared with no exposure, brain tumor risk increased with cumulative dose (>0 to <1 mGy: HR, 1.12 [95% CI, 1.01-1.26]; 1 to <5 mGy: HR, 1.71 [95% CI, 0.88-2.96]; 5 to <50 mGy: HR, 1.86 [95% CI, 1.16-2.81]; 50 to <75 mGy: HR, 2.30 [95% CI, 1.64-3.12]; 75 to <100 mGy: HR, 2.02 [95% CI, 1.13-3.30]; 100 to <150 mGy: HR, 2.81 [95% CI, 1.53-4.66]; ≥150 mGy: HR, 3.85 [95% CI, 2.43-5.75]). Cumulative dose was associated with brain tumor risk overall (ERR per 100 mGy, 1.27 [95% CI, 0.83-1.77]; P < .001), with stronger associations for aggressive histologies (ERR per 100 mGy, 1.51 [95% CI, 1.00-2.11]; P < .001). By age 21 years, exposure comparable to 1 head CT was associated with 7.9 excess brain tumors per 10 000 children, or approximately 1 excess tumor per 1266 head CT examinations. The estimated population-attributable fraction was 10.1% (95% CI, 5.8%-14.2%). CONCLUSIONS AND RELEVANCE: Medical imaging in children and adolescents was associated with a dose-related increase in brain tumor risk. These findings support careful clinical justification and dose minimization when pediatric imaging using ionizing radiation is indicated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Occupational exposure to ionising radiation and central nervous system tumour mortality: a pooled analysis of Korean, French and US medical radiation workers.BMJ public health · 2026
- Assessment of Cumulative Dose and Cancer Risk Induced by Pediatric Head CT Examinations: A Moroccan Retrospective Study.Health physics · 2026
- Radiation safety and cancer risks in pediatric computed tomography: a systematic review of large-scale cohort studiesFrontiers in Pediatrics · 2026
- Mobile phone use and brain tumour risk: Evidence from the UK Biobank Cohort.Environmental research · 2026
- Cumulative Ionizing Radiation Exposure in Deceased-Donor Kidney Transplant Recipients.Journal of clinical medicine · 2026
- Time Trends in Brain Tumour Incidence in the Nordic Countries, 1980–2022Diseases · 2026