JAMA

Left Bundle-Branch Area Pacing vs Right Ventricular Pacing for Atrioventricular Block and Preserved Left Ventricular Function: The LEAP-Block Randomized Clinical Trial.

Xiaofei Li, Haixiong Wang, Wenjuan Zhang, Ling You, Chunguang Qiu, Fengpeng Jia, Zhimin Liu, Xiaoming Li,

Cardiac Arrhythmia Center, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. · Department of Cardiology, Shanxi Cardiovascular Hospital, Taiyuan, Shanxi, China.

Randomised · n=551

Key points

From the paper's conclusion
  • Among patients with atrioventricular block and preserved LVEF requiring high-burden ventricular pacing, LBBAP was superior to RVP in reducing the risk of the composite end point of all-cause death, HF events, or upgrade to biventricular pacing at 24 months.

Abstract

IMPORTANCE: For patients with atrioventricular block requiring high-burden ventricular pacing, the optimal pacing strategy to reduce heart failure (HF) and all-cause mortality remains uncertain. Robust comparative evidence on the clinical outcomes of left bundle-branch area pacing (LBBAP) vs right ventricular pacing (RVP) in this population is needed. OBJECTIVE: To compare 24-month clinical outcomes of LBBAP vs RVP in patients with atrioventricular block and preserved left ventricular ejection fraction (LVEF; ≥50%). DESIGN, SETTING, AND PARTICIPANTS: The LEAP-Block study was a prospective, multicenter, randomized, controlled, superiority trial conducted across 14 Chinese hospitals from January 2021 to August 2025, with last follow-up on June 3, 2025. Of 551 patients with LVEF 50% or greater requiring ventricular pacing who underwent eligibility assessment, 499 with anticipated ventricular pacing greater than 40% were randomized. INTERVENTIONS: Patients were randomized in a 1:1 ratio to LBBAP (n = 249) or RVP (n = 250). MAIN OUTCOMES AND MEASURES: The primary end point was a composite of all-cause death, HF events, or upgrade to biventricular pacing at 24 months. Secondary end points included pacing-induced cardiomyopathy and device-related complications. RESULTS: The primary analysis included 482 patients (LBBAP, n = 242; RVP, n = 240; mean age, 67 years; 46% female). Acute procedure success was comparable between the 2 groups (LBBAP, 237/242 [97.9%] vs RVP, 239/240 [99.6%]; P = .22), with left bundle-branch capture confirmed in 188 of 236 patients (79.7%). LBBAP significantly reduced the primary end point vs RVP (2.4% vs 12.5%, respectively; absolute risk difference, -10.1% [95% CI, -16.8% to -3.4%]; P = .003). Among secondary outcomes, the LBBAP group had fewer HF events (3.4% vs 11.3%; -7.9% [95% CI, -13.0% to -2.8%]). No significant differences were observed in all-cause death, biventricular pacing upgrade, device-related complications, or pacing-induced cardiomyopathy. The 24-month Kaplan-Meier estimated cumulative incidence of the primary end point was 5.0% for LBBAP vs 13.2% for RVP (hazard ratio, 0.37 [95% CI, 0.19 to 0.73]; P = .004). LBBAP superiority was consistent across all prespecified subgroups. CONCLUSIONS AND RELEVANCE: Among patients with atrioventricular block and preserved LVEF requiring high-burden ventricular pacing, LBBAP was superior to RVP in reducing the risk of the composite end point of all-cause death, HF events, or upgrade to biventricular pacing at 24 months. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04730921.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers